Form-4
APPLICATION FOR AMENDMENT IN ENVIRONMENTAL CLEARANCE
(To be filled up by User Agency)
1.
Details of Project
Proposal No. :
SIA/TG/MIS/137851/2020
(a) Name of the project :
M/s. Terminus KG Ventures (P) Ltd – “ONE WEST”
(b) Name of Company / Organisation. :
TERMINUS KG VENTURES PRIVATE LIMITED
(c) Registered Address. :
SUITE NO:902, LEVEL 9, SLN TERMINUS, BESIDE BOTANICAL GARDEN, SY.NO:133, GACHIBOWLI, HYDERABAD Telangana 500032
(d) Legal Status of the Company. :
Private
(e) Joint Venture (Yes/No) :
No
2.
Address for the Correspondence
(a) Name of the Applicant. :
Solipuram PrabhakarReddy
(b) Designation (Owner/Partner/CEO) :
Director
(c) Address
:-
State :
Telangana
District :
Rangareddi
Town / Village :
No
(d) Pin Code :
500032
(e) Email :
propertymanager@terminus-global.com
(f) Telephone no :
64564155
(g) Fax no :
00
(h) Mobile no :
9963570009
(i) Contact Person. :
Solipuram
(j) Website (if any) :
No
3.
Category of the Project/Activity as per Schedule of EIA Notification,2006
(a). Major Activity. :
8(a) Building and Construction projects
Minor Activity :
No
Major Sub Activity. :
No
Minor Sub Activity :
No
(b). Category :
B2
Reason for applicant at central level/state level(in case of B1 and B2 ):
No
(c). Reason :
No
EAC Concerned (for category A Projects Only ):
No
4.
Location of the Project
(a) Plot No/Survey No/Khasra No :
88/E & 88/A
(b) Village :
No
(c) Tehsil :
No
(d) District :
No
(e) State :
No
(f) Pin Code :
500008
(g) Bounded Latitudes (North) :
Yes
From :
Degree:17, Minutes : 24, Seconds :54
To :
Degree:17, Minutes : 24, Seconds :56
(h) Bounded Longitudes (East) :
Yes
From :
Degree:78, Minutes : 21, Seconds :14
To :
Degree:78, Minutes : 21, Seconds :18
(i) Survey of India Topo Sheet No :
56 K / 7
5
Details of Environmental Clearance
(a) Project Name :
M/s.Terminus KG Ventures Pvt Ltd
(b) MoEF&CC / SEIAA File No :
SEIAA/TS/OL/RRD-177/2017
(c) Date of issue of EC :
22/12/2017
(d) Uploaded EC letter :
6
Details of Consent to Operate
(i) Whether Consent to operate obtained (Yes/No) ? :
No
7
Amendment Sought for
Amendment in Configuration/ Amendments in Clearance condition/ Other (specify) :
Amendment in configuration of BUA from 1,19,303.0 Sqm to 1,25,097.41 Sqm
8
Details of Product (as per the approved EC)
Details of Products
S.no
Product / Activity (Capacity/ Area).
Quantity
Unit
Mode of Transport/ Transmission of Product
1
Mixed use development project
119303.0
Others
Road
9
Details of Configuration (Multiple Entries Allowed)
Details of Configurations
S.no
Plant/ Equipment/ Facility
Existing Configuration
Proposed Configuration
Final configuration after Amendment
Remarks if Any
1
WASTE WATER GENERATION
264.80 KLD
348.0 KLD
348.0 KLD
2
STP CAPACITY
275.0 KLD
420.0 KLD
420.0 KLD
3
VEHICLES PARKING
4W-1075 & 2W-75
4W -1507 & 2W 567
4W-1507 & 2W 567
4
STP SLUDGE
20.0
35.0
35.0
5
Net plot area
9461.37 Sqm
9461.79 Sqm
9461.79 Sqm
6
Parking area
35324.0 sqm
35816.41
35816.41
7
TOTAL WATER REQUIREMENT
608.15 KLD
553.0
553.0
8
NO. OF FLOORS
3B+G+20 UPPER FLOORS
3B + G+1+3 STILT+20 UPPER FLOORS
3B+G+1+3 STILT+20 UPPER FLOORS
9
BUA SQM
119303
125097.41
125097.41
10
SOLID WASTE
865.13 KG/DAY
2063.0 KG / DAY
2063.0 KG/DAY
11
Project cost
150.0
160.0
160.0
12
D.G.SETS
4 * 1500 KVA
4 * 1500 KVA
4*1500 KVA
13
Floors BUA
83979.0 Sqm
89281.0 Sqm
89281.0 Sqm
10
Reasons for Amendment
Reasons for Amendment :
Due to change in project proposal from Mixed use development project to Mixed development commercial and office space. Due to this our project built up area is increasing from 1,19,303.0 sqm to 1,25,097.41 sqm. hence we are requesting to amendment in issued EC
11
Any Other Amendment required
Any Other Amendment Required
S.no
Reference of Approved EC
Description as per Approved EC
Description as per Proposal.
Remarks
1
SEIAA/TS/OL/RRD-177/2017
119303.0 SQM BUA
125097.41 SQM BUA
CHANGE IN BUA
12
Details of EIA Consultant
Have you hired Consultant for preparing document (Yes/No) ? :
Yes
(i) Accereditation No :
NABET/EIA/1922/IA0043
(ii) Name of EIA Consultant :
MS SPACE ENVIRO SOLUTIONS
(iii)Address :
H.NO-1-4-69/7, Street no. 8, Habsiguda,Near Heritage fresh,Hyderabad.
(iv)Mobile No:
9848199516
(v)Landline No :
04048503377
(vi)E-mail Id :
info@spaceenviro.com
(vii)Category of Accreditation :
A
(viii)Sector of Accreditation :
1(a)
(ix)Validity of Accreditation :
05-03-2022
(x)Uploaded certificate of Accreditation certified by QCI/NABET :
13.
Documents to be Attached
(a) Uploaded addendum to EIA/EMP Report:
(b) Uploaded Copy of revised -Feasibility Report /Detailed Project Report (DPR) / Detailed Engineering Report / Detailed Conceptual Plan / Approved Mining Plan (in case of mining proposals):
(c) Uploaded Copy of final Layout Plan:
(d)Uploaded Cover Letter duly signed by the project proponent or authorized person:
(e)Uploaded a copy of authorization duly signed by the project proponent in support of the person making this application on behalf of the User Agency:
(f)Uploaded Additional File, If any:
Essential Details Sought
Essential Details Sought
S.no.
EDS Sought Date
EDS Sought
Letter
NIL
Additional Detail Sought:
NIL
14.
Undertaking
(a):
I hereby give undertaking that the data and information given in the application and enclosures are true to be best of my knowledge and belief and I am aware that if any part of the data and information found to be false or misleading at any stage, The project will be rejected and clearance given, If any to the project will be revoked at our risk and cost. In addition to above, I hereby give undertaking that no activity / construction / expansion has since been taken up.
(b)Name :
Solipuram PrabhakarReddy
(c)Designation:
Director
(d)Company:
TERMINUS KG VENTURES PRIVATE LIMITED
(e)Address:
SUITE NO:902, LEVEL 9, SLN TERMINUS, BESIDE BOTANICAL GARDEN, SY.NO:133, GACHIBOWLI, HYDERABAD Telangana 500032