APPENDIX I | (See Paragraph-6) | FORM 1 | | Note : If space provided against any parameter is inadequate, Kindly upload supporting document under 'Additional Attachments if any' at the last part of the Form1. Please note that all such Annexures must be part of single pdf document. | (I) Basic Information | | | Is your project Comes under Notified Industrial Area | NA |
| | Whether proposal involved violation of EIA notification | N/A | | Weather Consent to Establishment Obtained | N/A | | Upload copy of CTE | N/A |
| 1. | |
Name of the Project/s | Development of Industrial Park at Rambilli | Brief summary of project | Annexure-Brief summary of project | Proposal Number | IA/AP/NCP/84097/2018 | Project Cost | 68100 lacs | |
| 2. | |
S. No. in the schedule | 7(c) Industrial estates/ parks/ complexes/ areas, export processing Zones
| Project Sector | INFRA-1 | |
| 3. | Proposed capacity/area/length/tonnage to be handled/command area/lease area/number or wells to be drilled | 1025 ha (2532 acres) ha. | | 4. | New/Expansion/Modernization | New | | | 5. | Existing Capacity/Area etc. | 0 ha. | | 6. | Category of project i.e. 'A' or 'B' | A | | 7. | Does it attract the general condition? If yes, please specify | No | | | 8. | Does it attract the specific condition? If yes, please specify | Yes | 8.(a) | If any Industrial Estate/Complex / Export processing Zones /Special Economic Zones/Biotech Parks / Leather Complex with homogeneous typeof industries such as Items 4(d), 4(f), 5(e), 5(f), or those Industrial estates with pre –defined set of activities (not necessarily homogeneous, obtains prior environmental clearance, individual industries includingproposed industrial housing within such estates /complexes will not be required to take prior environmental clearance, so long as the Terms and Conditions for the industrial estate/complex are complied with (Such estates/complexes must have a clearly identified management with the legal responsibility of ensuring adherence to the Terms and Conditions of prior environmental clearance, who may be held responsible for violation of the same throughout the life of the complex/estate | (a) i. Status of the Environmental Clearance to the Project | EC application yet to be submitted | | | 9. | |
Location of the project | Krishnapalem, Gorapudi, Z.Chintuva, lalamkoduru revenue villages | Shape of the project land | Block (Polygon) | Uploaded GPS file | Annexure-GPS file | Uploaded copy of survey of India Toposheet | Annexure-Survey of india toposheet | Plot/Survey/Khasra No. | Gorapudi - 1p, 2 to 74, 76 to 85, 88 to 96, 97p, 98 to 104, 108 and 109
Z. Chintuva – 31 to 58, 59P, 60 to 67, 82 to 99, 100P, 101 to 104, 105P, 106 to 116, 117P, 118P, 119 to 121, 122P, 123 to 146, 152 to 156, 164 to 175, 176P, 177 to 185, 192 to 195, 197 to 199, 200P, 201 to 238
Lalamkoduru - 15/31, 81 part, 88 part, 92/1, 122 to 127, 128 part, 129 to 134
Krishnampalem – 24 to 34, 43 to 59, 60 to 108, 116 to 126, 136 to 139 | Town / Village | Krishnapalem, Gorapudi, Z.Chintuva, lalamkoduru revenue villages | State of the project | Andhra Pradesh | |
| Details of State of the project |
---|
S.no | State Name | District Name | Tehsil Name |
---|
(1.) | Andhra Pradesh | Visakhapatnam | Rambilli | | 10. | |
Nearest railway station along with distance in kms | Yelamanchili, 10.4 km | Nearest airport along with distance in kms | Visakhapatnam, 35.5 km | |
| 11. | Nearest Town/City/District Headquarters along with distance in kms | Yelamanchili , 9.7 km | | 12. | Village Panchayats, Zila Parishad, Muncipal Corporation, Local body (Complete postal address with telephone nos. to be given) | Krishnapalem, Gorapudi, Z.chintuva, Lalamkoduru village panchayats, Rambilli Mandal, Yelamanchili Taluka, Pin – 531061. MPDO office Ph. no. 08931 - 234280 | | 13. | Name of the Applicant | Vice Chairman and Managing Director | | 14. | Registered Address | ANDHRA PRADESH INDUSTRIAL INFRASTRUCTURE CORPORATION, 4th FLOOR, PARISRAMA BHAVAN, 5-9-58/B, FATEH MAIDAN ROAD. | | 15. | |
Address for correspondance: | Name of the Company | ANDHRA PRADESH INDUSTRIAL INFRA STRUCTURE CORPORATION | Name of the Applicant | Vice Chairman and Managing Director | Designation (Owner/ Partner/ CEO) | VCMD | Pin code | 522503 | E-mail | apiicempcell@gmail.com | Telephone No. | 0863-2381850 | Fax No. | 0863- | Copy of documents in support of the competence/authority of the person making this application to make application on behalf of the User Agency . | Annexure-Uploaded Copy of documents in support of the competence/authority | |
| 16. | Details of Alternative Sites examined, if any. Location of these sites should be shown on a toposheet | No | |
| 17. | Whether part of Interlinked projects? | No | | 18. | Whether separate application of Interlinked project has been submitted? | N/A | | 19. | If Yes, MoEF file number | N/A | Date of submission | N/A | | | | 21. | Whether the proposal involves Approval/ Clearance under: if yes, details of the same and their status to be given | (i) Whether the proposal involves approval/clearance under the Forest (Conservation) Act,1980? | No | (ii) Whether the proposal involves approval/clearance under the wildlife (Protection) Act,1972? | No | (iii) Whether the proposal involves approval/clearance under the C.R.Z notification, 2011? | Yes | | | | 23. | Whether any Forest Land Involved? | No | Area of Forest land Involved (hectares) | N/A | |
| 24. | Whether there is any litigation pending against the project and/or land in which the project is proposed to be set up? | No | (a) Name of the Court | N/A | (b) Name of the Sub court | N/A | (c) Case No. | N/A | (d) Orders/directions of the court, if any and relevance with the proposed project | N/A | |
| 1 | Construction, operation or decommissioning of the Project involving actions, which will cause physical changes in the locality (topography, land use, changes in water bodies, etc.) | S.No | Information/Checklist confirmation | Yes/No | Details there of (with approximate quantities/rates, wherever possible) with source of information data | 1.1 | Permanent or temporary change in land use, land cover or topography including increase in intensity of land use (with respect to local land use plan) | Yes | Land requirement for development of the proposed IP is about ~1025 ha (2532 Acres). There will be a permanent change in land use, land cover and topography due to the development of proposed IP. Change in the land use to industrial is envisaged due to the proposed project. | 1.2 | Clearance of existing land, vegetation and buildings? | Yes | The site is mostly comprised of Agriculture, plantation and fallow land, Barren unculturable, wastelands, Scrub lands, water Bodies, stream and settlements.
Clearance of vegetation, buildings shall be carried out as per Project requirement. | 1.3 | Creation of new land uses? | Yes | As per the requirement for the development of IP and its supporting infrastructure facilities new land use will be created. Master Plan layout is given in the Pre-Feasibility Report. | 1.4 | Pre-construction investigations e.g. bore houses, soil testing? | Yes | All the requisite Pre-construction investigations will be carried out for the area to be developed | 1.5 | Construction works? | Yes | The buildings, necessary civil structures will be constructed along with infrastructure facilities. The following are the target industrial sectors proposed: Pharmaceuticals, Chemicals, Industrial and Consumer Electronics, Auto and Auto components, Aerospace and defence, Light and heavy Engineering, CRZ permissible hazardous material storage's, Building Materials Industry/Non Metallic minerals, MSME (Leather, Plastics, wood etc.,); Food and Agro Processing Industry; Textile and apparel | 1.6 | Demolition works? | Yes | Scattered dwellings located in project site will be relocated, demolition of buildings/structure will be carried out | 1.7 | Temporary sites used for construction works or housing of construction workers? | Yes | Unskilled workforce from nearby villages & towns will be engaged for construction works.
Temporary construction worker camps for semi-skilled and skilled will be located near the project site and adequate provision of water, power, fuel, medical facilities and sanitation facilities will be ensured | 1.8 | Above ground buildings, structures or earthworks including linear structures, cut and fill or excavations and fill or excavations | Yes | As per development plan/ Master plan requirements which include Industrial/Administrative buildings, assembly/manufacturing shed, logistics, support & Social Infrastructure facilities will be constructed. Power Transmission, Storm water, effluent & sewage conveyance networks and Treatment facilities will be developed. Topsoil excavated during construction activities will be used for construction work/landscape development in project site is envisaged as a part of development plan | 1.9 | Underground works including mining or tunnelling? | Yes | As per project requirement such as water supply, electrical and electronic transmission lines, storm drainage system & waste water conveyance system etc., will be developed | 1.10 | Reclamation works? | No | | 1.12 | Offshore structures? | No | Existing Marine outfall system including conveyance pipeline of APSEZ will be used for disposal of treated wastewater | 1.13 | Production and manufacturing processes? | Yes | The proposed Industrial Park is aimed to attract investments in the following target industrial sectors proposed:
• Pharmaceuticals; Chemicals
• Industrial and Consumer Electronics
• Auto and Auto components
• Aerospace and defence
• Light and heavy Engineering CRZ permissible hazardous material storages
• Building Materials Industry/Non Metallic minerals
• MSME (includes Leather, Plastics, wood etc.,); Food and Agro Processing Industry; Textile and apparel | 1.14 | Facilities for storage of goods or materials? | Yes | The facilities required for storage of raw materials and finished products such as warehousing, storage facilities etc. will be developed within the industrial units proposed in the IP. Temporary storage sheds are proposed during construction phase. | 1.15 | Facilities for treatment or disposal of solid waste or liquid effluents? | Yes | Industries willing for own treatment facilities shall be developed in their premises. If industry wants to utilise common facilities, effluent&sewage generated in industrial area will be treated in 11.5 MLD CETP. Treated wastewater will be disposed into sea through APSEZ marine outfall. Sewage from residential/R&R area will be treated in 1.2 MLD STP. Treated sewage will be reused for greenbelt&toilet flushing. Hazardous waste will be sent to proposed common TSDF, till then JNU TSDF will be used | 1.16 | Facilities for long term housing of operational workers? | Yes | Long term housing for operational workers will be provided.
In residential zone, housing and allied infrastructure like educational facility, health care facility, recreational facilities, cultural facilities, playgrounds and community facilities, etc. are proposed | 1.17 | New road, rail or sea traffic during construction or operation? | Yes | Construction Phase Traffic:
• Vehicles involved in transport human & material resource in and out of project area.
• Construction equipment/ machinery and material shall be brought to site by road.
Operation Phase Traffic:
• Vehicles involved for the transportation of men and raw material, finished goods and waste.
• Road/Rail traffic during import/export of raw materials and finished goods | 1.18 | New road, rail, air water borne or other transport infrastructure including new or altered routes and stations, ports, airports etc? | Yes | The strategic location of site with good transport facility offers comfortable access to site and other cities of India.
However, in order to provide dedicated access to IP, access roads are proposed to be developed | 1.19 | Closure or diversion of existing transport routes or infrastructure leading to changes in traffic movements? | No | The proposed facility shall not attract any closure or diversion of the existing major transport routes | 1.20 | New or diverted transmission lines or pipelines? | Yes | There are power lines and poles in the project area which will be rerouted in consultation with relevant department.
New Power transmission and water supply pipelines and wastewater conveyance pipelines will be developed.
The internal road corridor will include all the primary utility pipelines and cables | 1.21 | Impoundment, damming, culverting, realignment or other changes to the hydrology of watercourses or aquifers? | Yes | Existing major streams in the project site will be retained by providing adequate green buffer. Minor streams will be rerouted as per the drainage plan. Adequate Storm water drainage system will be provided to ensure that the drainage pattern of the area is maintained | 1.22 | Stream crossings? | Yes | A Small stream is passing on the northern side proper culverts and adequate buffer will be provided | 1.23 | Abstraction or transfers of water from ground or surface waters? | Yes | Total water demand for the proposed IP is ~20.77 MLD but considering the reuse of treated sewage in the proposed STP, the net fresh water demand is ~19.8 MLD. The quantity of water required for fire protection is 900 KL.
The fresh water will be sourced from the industrial water supply scheme for APIIC from Yeleru Left Main Canal (YLMC) which is located at ~16 km from the project site | 1.24 | Changes in water bodies or the land surface affecting drainage or run-off? | Yes | Grading of project site will be planned in such a way that the natural drainage pattern will not be much affected | 1.25 | Transport of personnel or materials for construction, operation or decommissioning? | Yes | Construction Phase: Transportation of construction materials such as cement, aggregates, rock, sand, steel, waste etc. and movement of construction workers by vans or buses
Operation Phase: Transportation of raw materials/finished goods/waste. Movement of workforce from the nearby habitations to the project site | 1.26 | Long-term dismantling or decommissioning or restoration works? | No | | 1.27 | Ongoing activity during decommissioning which could have an impact on the environment? | No | | 1.28 | Influx of people to an area in either temporarily or permanently? | Yes | Temporary and limited during construction phase.
Marginal and permanent during operation phase | 1.29 | Introduction of alien species? | No | | 1.30 | Loss of native species or genetic diversity? | No | | 1.31 | Any other actions? | No | | | 2 | Use of Natural resources for construction or operation of the Project (such as land, water, materials or energy, especially any resources which are non-renewable or in short supply): | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 2.1 | Land especially undeveloped or agricultural land (ha) | Yes | Land proposed for development of IP near Rambilli is ~1025 ha (2532 Acres).
The site is comprised of mostly scrub land, partly plantations, water bodies, single crop land and habitations etc. | 2.2 | Water (expected source & competing users) unit: KLD | Yes | Construction Phase - 1.0 MLD Source: Partly will be sourced water supply scheme of YLMC and partly from local municipality/panchayat.
Operation Phase: water demand for proposed IP is ~20.77 MLD but considering reuse of treated sewage in proposed STP, net fresh water demand is ~19.8 MLD. Water required for fire protection is 900 KL. Fresh water will be sourced from the industrial water supply scheme for APIIC from Yeleru Left Main Canal (YLMC) which is located at ~16 km from the project site | 2.4 | Construction material – stone, aggregates, sand / soil (expected source – MT) | Yes | Soil, sand, gravel and stone aggregates will be procured from nearby sources.
Topsoil excavated during construction activities will be stored and used for construction work/ landscape development/Greenbelt development within the project site | 2.5 | Forests and timber (source – MT) | Yes | As per project requirement wood materials (Wood Chips for walls, doors, floor, other interior, etc.) for construction/ operation if any will be sourced from licensed suppliers | 2.6 | Energy including electricity and fuels (source, competing users) Unit: fuel (MT),energy (MW) | Yes | Construction phase:
Power requirement: 5 mVA
Source: APTRANSCO and partly will be sourced through DG sets.
Operation phase:
Power requirement: 230 mVA
Source: APTRANSCO
Nearest substation details | 2.7 | Any other natural resources (use appropriate standard units) | No | | | 3 | Use, storage, transport, handling or production of substances or materials, which could be harmful to human health or the environment or raise concerns about actual or perceived risks to human health | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 3.1 | Use of substances or materials, which are hazardous (as per MSIHC rules) to human health or the environment (flora, fauna, and water supplies | Yes | As per requirement Production/manufacturing processes in IP will use various hazardous chemicals/materials. Protection programs shall be developed & implemented. Workers shall be protected from exposure to process chemicals including but not limited to: acids, bases, solvents, metals powders and metal sludge as well as toxic, cryogenic and pyrophoric gases. Risks associated with handling, storage of chemical/ equipment at IP & accordingly mitigation measures will be suggested in the EIA report | 3.2 | Changes in occurrence of disease or affect disease vectors (e.g. insect or water borne diseases) | No | | 3.3 | Affect the welfare of people e.g. by changing living conditions? | Yes | Communication and transportation facilities will improve. With the development of the project, direct and indirect employment will be generated during construction and operation phases. Direct employment of 39,000 will be generated. There will be improvement in living standards of the people in the surrounding region and general welfare will improve in the area as per capital income will go up in the post project period | 3.4 | Vulnerable groups of people who could be affected by the project e.g. hospital patients, children, the elderly etc. | Yes | The impact (both benevolent and malevolent) on nearby habitations will be studied and addressed in EIA considering all sensitive receptors if any | | 4 | Production of solid wastes during construction or operation or decommissioning (MT/month) | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 4.1 | Spoil, overburden or mine wastes | No | | 4.2 | Municipal waste (domestic and or commercial wastes) | Yes | The estimated municipal solid waste generation is 26 T/d. Municipal wastes in the form of canteen waste domestic waste etc. will be generated. Disposal of Solid waste will be carried out as per prevailing norms. Details regarding quantification's, collection, handling and disposal/management shall be covered in the EIA study | 4.3 | Hazardous wastes (as per Hazardous Waste Management Rules) | Yes | The estimated industrial solid waste generation is 88 T/d Hazardous waste will be sent to proposed TSDF by APIIC, until it is operational, TSDF at JNU pharma city will be used. Industries shall follow Hazardous Waste (Management and Handling) Rules | 4.4 | Other industrial process wastes | Yes | Non-hazardous industrial waste consists of recyclable and non-recyclable waste. Biodegradable waste will be mixed with MSW and given to approved vendors. Other recyclable waste will be sent to nearest recycling facility, if any for reuse. The details and disposal methods will be further evaluated during detail planning stage. Industrial e-waste will be handled and disposed as per the prevalent rules | 4.6 | Sewage sludge or other sludge from effluent treatment | Yes | Value addition options will be identified for waste management and adopted by individual industries. Sludge from process waste and CETP will be sent to the authorised TSDF site | 4.7 | Construction or demolition wastes | Yes | During construction phase, construction debris may be generated which will be segregated and whatever is re-saleable will be sold to buyers and rest of the waste will be used for filling up of low lying areas and development of internal roads and boundary walls | 4.8 | Redundant machinery or equipment | No | | 4.9 | Contaminated soils or other materials | No | It is not expected during normal operations. But in case of accidental spills, efforts will be taken to recover spilled material/ substances and subsequently corrective/ remedial actions will be taken. Improved engineering measures will be taken to prevent fugitive losses | 4.10 | Agricultural wastes | No | | 4.11 | Other solid wastes | No | | | 5 | Release of pollutants or any hazardous, toxic or noxious substances to air(Kg/hr) | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 5.1 | Emissions from combustion of fossil fuels from stationary or mobile sources | Yes | Construction phase: Emissions will be from the operation of DG sets, exhaust of construction equipment’s including moving vehicles/ trucks carrying human and material resource.
Operation phase: emissions from D.G sets, vehicular traffic & industrial units which would result in the build-up of particulate matter and gaseous emissions. All vehicles will have Pollution Under Control (PUC) Certificate as applicable; DG sets will ensure the stipulated standards for emission and others | 5.2 | Emissions from production processes | Yes | The emissions from production process are anticipated which include greenhouse gases, toxic, reactive, and corrosive substances. Suitable abatement measures as available such as Point of Use Systems will be presented in the EIA report. Relevant units proposed in the IP will adopt the necessary measures to control emissions | 5.3 | Emissions from materials handling including storage or transport | Yes | Adequate measures will be taken during storage and handling of material. Regular inspection, barriers at the perimeter of storage materials, proper maintenance of vehicles etc. The details of the emissions and control measures will be provided in EIA report | 5.4 | Emissions from construction activities including plant and equipment | Yes | Emissions from diesel operated pumps, concrete mixers, equipment vibrators, excavators during construction activities. These equipments will be maintained properly to ensure minimum emissions. However, construction activity will be for a short duration and restricted within boundary | 5.5 | Dust or odours from handling of materials including construction materials, sewage and waste | Yes | Dust generated due to handling of construction material will be controlled by sprinkling of water. Dust generation is anticipated during operation phase also while handling raw materials and finished goods.
Odour from treatment system is envisaged, odour mitigation measures will be followed. Dust Suppression system and Greenbelt will be provided | 5.6 | Emissions from incineration of waste | No | | 5.7 | Emissions from burning of waste in open air (e.g. slash materials, construction debris) | No | | 5.8 | Emissions from any other sources | No | | | 6 | Generation of Noise and Vibration, and Emissions of Light and Heat: | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 6.1 | From operation of equipment e.g. engines, ventilation plant, crushers | Yes | Noise generating from Vehicular movement, Construction equipment & activities. Effect of the noise is mostly localized and temporary will cease on completion of construction activity.
During Operation Phase, it shall be maintained <85 dB(A).
Some emission of light due to welding activities during construction & operations within the premises is temporary in nature.
Proper cooling /ventilation system will be used to extract/utilise the heat generated during operations | 6.2 | From industrial or similar processes | Yes | Different operation processes are expected to generate noise. Suitable control measure such as acoustic enclosure, plantation (green belt) around the site etc. would be provided to minimize the noise levels. All workers, working in the high noise areas would be provided with Personnel Protection Equipment’s (PPEs). Regularly maintaining operation equipment’s etc. will be taken to ensure the noise levels within prescribed limits | 6.3 | From construction or demolition | Yes | During demolition and construction, there will be noise generation. Personnel Protection Equipment (PPE) will be provided to workers | 6.4 | From blasting or piling | Yes | Piling will be carried out as per project requirement; there will also be blasting activity during the construction stage to remove stony waste/rocky materials. Necessary precautions and Personal Protecting Equipment will be provided to the work force | 6.5 | From construction or operational traffic | Yes | Traffic movement during operation phase will increase the noise levels. Suitable measures like paved roads; regular maintenance of vehicles shall be ensured | 6.6 | From lighting or cooling systems | Yes | During welding, cutting, electrical lighting, power circuits, drilling etc., lighting may be produced where workers will be provided with necessary PPE.
Air conditioning and ventilation system generate noise and necessary enclosure and vibration control measures will be provided | 6.7 | From any other sources | No | | | 7 | Risks of contamination of land or water from releases of pollutants into the ground or into sewers, surface waters, groundwater, coastal waters or the sea: | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 7.1 | From handling, storage, use or spillage of hazardous materials | Yes | Hazardous materials will be stored and handled as per the provisions of the Manufacturer, Storage and Import of Hazardous Chemical Rules, Hazardous Wastes (Management and Handling) Rules, 1989 and Amendments thereof by Individual industries. During accidental spill if any. Spill contingency plan will be adopted to prevent the release of pollutant in to the environment by each industry | 7.2 | From discharge of sewage or other effluents to water or the land (expected mode and place of discharge) | No | Industries willing for own treatment facilities shall be developed in their premises. If industry wants to utilise common facilities, effluent&sewage generated in industrial area will be treated in 11.5 MLD CETP. Treated wastewater will be disposed into sea through APSEZ marine outfall. Sewage from residential/R&R area will be treated in 1.2 MLD STP. Treated sewage will be reused for greenbelt&toilet flushing. Hazardous waste will be sent to proposed common TSDF, till then JNU TSDF will be used | 7.3 | By deposition of pollutants emitted to air into the land or into water | Yes | Industries willing for own treatment facilities shall be developed in their premises. If industry wants to utilise common facilities, effluent&sewage generated in industrial area will be treated in 11.5 MLD CETP. Treated wastewater will be disposed into sea through APSEZ marine outfall. Sewage from residential/R&R area will be treated in 1.2 MLD STP. Treated sewage will be reused for greenbelt&toilet flushing. Hazardous waste will be sent to proposed common TSDF, till then JNU TSDF will be used | 7.4 | From any other sources | No | | 7.5 | Is there a risk of long term build up of pollutants in the environment from these sources? | No | Not envisaged in view of proposed pollution preventive and control measures to comply with the prescribed statutory norms | | 8 | Risk of accidents during construction or operation of the Project, which could affect human health or the environment | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 8.1 | From explosions, spillages, fires etc from storage, handling, use or production of hazardous substances | Yes | Risks associated with handling, storage of hazardous materials will be covered in the EIA study and accordingly mitigation measures will be suggested in the EIA report. Hazardous materials if any will be stored and handled as per the provisions of the manufacturer, storage and import of Hazardous Chemical Rules, Hazardous Wastes (Management and Handling) Rules, 1989 and Amendments thereof to avoid accidents during construction or operational phase | 8.2 | From any other causes | No | | 8.3 | Could the project be affected by natural disasters causing environmental damage (e.g. floods, earthquakes, landslides, cloudburst etc)? | Yes | Proposed project site falls under Seismic Zone II (Low Risk Zone) as per IS 1893 (Part I). Probable affects due to natural disasters which include floods, etc., will be studied and addressed in the EIA report | | 9 | Factors which should be considered (such as consequential development) which could lead to environmental effects or the potential for cumulative impacts with other existing or planned activities in the locality | S.No | Information/Checklist confirmation | Yes/No | Details thereof (with approximate quantities/rates, wherever possible) with source of information data | 9.1 | Lead to development of supporting utilities, ancillary development or development stimulated   by the project which could have impact on the environment e.g.:
- Supporting infrastructure (roads, power supply,waste or waste water treatment, etc.)
- housing development
- extractive industries
- supply industries
- Other
| Yes | Development of the proposed project will lead to overall socio-economic development of region.
Necessary supportive utilities, infrastructure, housing, etc. to cater the requirements of the project will be developed | 9.2 | Lead to after-use of the site, which could have an impact on the environment | No | The proposed project would be a permanent establishment | 9.3 | Set a precedent for later developments | Yes | The proposed development would lead to various developmental activities in the region | 9.4 | Have cumulative effects due to proximity to other existing or planned projects with similar effects | Yes | Cumulative effects, if any, will be addressed in the EIA study | | (III) | Environmental Sensitivity | S.No | Areas | Name/Identity | Aerial distance (within 15km.) Proposed project location boundary | 1 | Areas protected under international conventions, national or local legislation for their ecological, landscape, cultural or other related value | No | | 2 | Areas which are important or sensitive for ecological reasons - Wetlands, watercourses or other water bodies, coastal zone, biospheres, mountains, forests | Yes | • Bay of Bengal - 0.2km, E
• Sitapalem PF - 0.05km, SE
• Rambilli RF – 0.05 km, W
• Pudimadaka R.F - 2.9km, NE
• Panchadarla R.F - 7.2km, N
• Gokivada R.F - 3.6km, NNW
• Vemagiri R.F - 9.7km, NW
• Kalavalapalli R.F - 1.4km, W
• Rambilli P.F - 1.1km, WSW | 3 | Areas used by protected, important or sensitive species of flora or fauna for breeding, nesting, foraging, resting, over wintering, migration | Yes | • Sitapalem PF - 0.05km, SE
• Rambilli RF – 0.05 km, W
• Pudimadaka R.F - 2.9km, NE
• Panchadarla R.F - 7.2km, N
• Gokivada R.F - 3.6km, NNW
• Vemagiri R.F - 9.7km, NW
• Kalavalapalli R.F - 1.4km, W
• Rambilli P.F - 1.1km, WSW | 4 | Inland, coastal, marine or underground waters | Yes | • Bay of Bengal - 0.2km E
• Sani Kaluva - 9.4km NE
• Sharada River - 3.6km NW
• Rama Sagaram - 9.5km WSW
• Mala Gedda - 7.4km WSW
• Varaha River - 9.3km WSW | 5 | State, National boundaries | No | | 6 | Routes or facilities used by the public for access to recreation or other tourist, pilgrim areas | Yes | • SH 97 - 3.4 NNW
• NH-16 (AH 45) - 9.7 NW | 7 | Defence installations | No | | 8 | Densely populated or built-up area | Yes | • Elamanchili – 9.7 km NW
• Atchutapuram – 9.4 km NE | 9 | Areas occupied by sensitive man-made land uses (hospitals, schools, places of worship, community facilities) | Yes | • Elamanchili – 9.7 km NW
• Atchutapuram – 9.4 km NE | 10 | Areas containing important, high quality or scarce resources.(ground water resources,surface resources,forestry,agriculture,fisheries,tourism,minerals) | Yes | • Sitapalem PF - 0.05km, SE
• Rambilli RF – 0.05 km, W
• Pudimadaka R.F - 2.9km, NE
• Panchadarla R.F - 7.2km, N
• Gokivada R.F - 3.6km, NNW
• Vemagiri R.F - 9.7km, NW
• Kalavalapalli R.F - 1.4km, W
• Rambilli P.F - 1.1km, WSW | 11 | Areas already subjected to pollution or environmental damage.(those where existing legal environmental standards are exceeded) | No | | 12 | Areas susceptible to natural hazard which could cause the project to present environmental problems (earthquakes, subsidence, landslides, erosion, flooding or extreme or adverse climatic conditions) similar effects | No | Proposed development area falls under
Seismic Zone II (Low Damage Risk Zone) as
per IS 1893 (Part I). During the design stage, the effects from natural disasters will be considered as per IS: 1893 (Part-1):2002 and necessary precautionary measures would be built-in /implemented. | | (IV) | Proposed Terms of Reference for EIA studies | | Essential Detail Sought: |
---|
Sno. | EDS Letter | Remarks | Date of EDS |
---|
1. | NA | The correction have been made as per the instruction received | 30 Nov 2018 | 2. | NA | Please provide following information/documents:
1. List of A category and B category industries
2. documents in support of the competence/authority. At present, copy of covering letter has been attached.
3. None of the figures/maps in PFR document are visible and readable. | 26 Nov 2018 | | Additional Detail Sought: |
---|
Sno. | ADS Letter | Remarks | Date of ADS |
---|
1. | ADS Reply Letter | Request to consider the project in next upcoming meeting | 06 Aug 2019 | 2. | NA | In view of above, the EAC during its 204th meeting of EAC (Infra-1), held on 17th December, 2018, the EAC (Infra-1) deferred the proposal for want of following information:
(i) Certificate from APPCB that proposed industrial area is more than 2 km away from the Critically Polluted Area.
(ii) Certification from APPCB stating that no activity has been started in the Krishnapalem Industrial Area for which EC was granted.
(iii) Copy of Board of Directors regarding approval of establishment of the proposed industrial area.
(iv) Copy of Government order for land acquisition.
(v) Surrender of Krishnapalem Environmental clearance before applying for integration with the proposed industrial area.
(vi) Submission of revised Form-1 of application with details of integration of Krishnapalem Indu | 11 Jan 2019 | | (V) | Undertaking | | I hereby give undertaking that the data and information given in the application and enclosures are true to be best of my knowledge and belief and I am aware that if any part of the data and information found to be false or misleading at any stage, the project will be rejected and clearance given, if any to the project will be revoked at our risk and cost. | V.(i) | Name of Applicant | Vice Chairman and Managing Director | Designation | VCMD | Name of Company (Applicant Name should not be given here) | ANDHRA PRADESH INDUSTRIAL INFRA STRUCTURE CORPORATION | Address | ANDHRA PRADESH INDUSTRIAL INFRASTRUCTURE CORPORATION, 4th FLOOR, PARISRAMA BHAVAN, 5-9-58/B, FATEH MAIDAN ROAD. |
|
|